HICLOVER TS20 Top-Loading Incinerator

HICLOVER TS20 Top-Loading Incinerator: Advantages, Applications, and Key Features


The HICLOVER TS20 is a compact, efficient, and versatile top-loading incinerator, designed especially for organizations that require a simple, safe, and reliable waste-management solution. Its defining feature―the top open door―makes loading waste faster, safer, and more ergonomic, offering clear advantages when compared with front-loading waste systems. As more facilities shift toward flexible and mobile waste-treatment solutions, the TS20 has become a preferred choice for small clinics, veterinary stations, farms, field laboratories, camp operations, and emergency-response units worldwide.


Top-Loading Advantage: Why the Top Open Door Matters

The top-loading design of the TS20 is engineered to simplify the whole waste-handling workflow. Opening from the top allows operators to directly drop waste into the chamber without the need to push or compress materials. This is especially valuable when disposing of paper waste, plastic packaging, laboratory residues, agricultural by-products, and small animal remains.

Key benefits of a top open door structure include:

  • Faster loading and less manual handling

  • Safer operation with reduced heat escape

  • More efficient feeding for irregular or bulky waste

  • Better compatibility with mobile and temporary installations

  • Simple daily operation for users with limited technical training

This loading method reduces operational errors, minimizes downtime between batches, and improves the consistency of combustion cycles.


Core Technical Features of HICLOVER Incinerators

Although compact, the HICLOVER TS20 shares the same engineering principles used across the company’s larger industrial models. These features ensure long service life, stable performance, and environmental protection:

  • Primary combustion chamber with reinforced refractory lining

  • Secondary chamber capable of high-temperature gas re-burning to reduce smoke and odor

  • Digital or PLC control system for temperature display, burner timing, and safety interlocks

  • Automatic burner operation with diesel, LPG, or natural gas options

  • Thermocouples for chamber monitoring to maintain optimal burning curves

  • Chimney with optional wet scrubber when higher air-quality compliance is required

  • High-efficiency insulation that reduces heat loss and fuel consumption

These standard HICLOVER features make the TS20 a reliable, low-maintenance unit suitable for long-term or short-term deployment.


Mobile and Flexible Deployment Options

A major advantage of the TS20 top-loading model is its compatibility with multiple mobile installation platforms. Many customers operate in environments where permanent construction is impractical. For this reason, HICLOVER offers the TS20 in several flexible packages:

  • Trailer-mounted mobile incinerator for farm inspections, vet services, and rural medical units

  • Containerized mobile system with ventilation, integrated chimney ports, and quick-connection wiring

  • Skid-mounted structure for rapid installation in construction sites, oil camps, and emergency shelters

  • Field-camp version designed for NGOs, humanitarian operations, and temporary waste-management stations

The low-installation requirement of the TS20―combined with its top open door for easy vertical loading―makes it ideal for these operational environments.


Application Scenarios Across Different Sectors

Because of its design simplicity and combustion reliability, the HICLOVER TS20 top-loading incinerator is widely used across various industries:

1. Medical and Clinical Waste
Small clinics, rural hospitals, and health posts use the TS20 for the destruction of infectious waste, dressings, PPE, and contaminated disposables, especially where central waste-treatment facilities are unavailable.

2. Veterinary and Poultry Waste
The top open door simplifies loading of small animal carcasses, feathers, by-products, and farm-related waste, making it a practical solution for poultry farms and veterinary labs.

3. Laboratory and Research Facilities
The model is suitable for biological samples, contaminated paper waste, and light packaging, where safe on-site destruction prevents cross-contamination.

4. Military Bases and Temporary Camps
Compact size and mobile configurations allow quick deployment in field bases, engineering camps, border posts, and disaster-response areas.

5. Commercial and Industrial Use
Workshops, hotels, and small manufacturing plants benefit from an on-site disposal system for paper waste, packaging, and light combustible materials.


Why the TS20 Stands Out in Its Category

The HICLOVER TS20 combines the simplicity of a small incinerator with the performance of a professional combustion system. It delivers:

  • Strong structural reliability

  • Low installation effort

  • High safety through digital/PLC control

  • Efficient burning with low smoke release

  • Excellent compatibility with mobile installations

  • User-friendly operations even for non-technical staff

These characteristics make it one of the most widely adopted top-loading incinerators in the small-capacity range.


Conclusion

The HICLOVER TS20 top-loading incinerator offers an effective balance of mobility, safety, convenience, and operational stability. Its top open door loading system directly improves workflow efficiency in all types of waste-management environments―from small clinics to agricultural operations, humanitarian missions, and remote-site industries. With robust engineering, dependable controls, and flexible deployment options, the TS20 continues to be one of the most versatile and globally trusted solutions in the HICLOVER product line.

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-11-24/09:55:38

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type